This Feature helps getting alarm notification for the outbound calls which can be configured through Trunk as well as Gateway, if the configuration need on trunk then that can be done on the alarm type such as ASR(Average Success Ratio), ACD (Average call duration), CIC (Concurrent Incomplete Calls) and if user needs alarm notification through Gateway then that is also possible, for getting the alarm notification one can configure the email ID so that the notification would be received there.

1. Installing the Add on for Alarm


Get Addons → Enterprise → Alarm


Addon will be installed successfully, re-login to use the feature!!

2. Configuring the Alarm Addon


Go to Switch→ Call Alarms→ Alarm Configuration


For creating alarm you need to click on option create alarm. After clicking on create you need will get different options like below.


As seen in above screenshot, options explained in below table for the alarm addon configuration.

Field Name

Field Description

NameEnter unique name of Alarm
Threshold valueSet threshold value as based on Type(ASR,ACD, CIC, Gateway, Active calls, Freeswitch) selection.
Period (in Secs)Set time in seconds for alarm configuration
StatusSet Alarm Status
EmailOn which email address you want this alarm alerts.
Type

On which email address you want this alarm alerts.

ASR -  ASR full form is answer-seizure ratio (ASR)

  • ASR is depends on the successful calls. It means average success ratio.
  • ASR = completed calls /total calls *100
  • If the ASR will go down below then your set threshold then you will get alert on your registered email address.

ACD -Average call duration.

  • It is the average duration count from total calls.
  • If the ACD will go down below your set threshold then you will get alert on registered email address.

CIC -Concurrent Incomplete Calls

  • It will depend on failed calls. If you have set it example --7 in threshold and in that set duration more then 7 calls failed then you will get alert on registered email.
  • If configured number of calls are not connected or rejected concurrently with the trunk then the alarm will be triggered.

Gateway

If you have selected gateway in type then the threshold will need to set 100 for this and you will get 2 options in ping type.

  • freeswitch- If you will select freeswitch then it will check ping from freeswitch.
  • console- If you will set console then it will go to console to ping provider IP manually.

If the gateway is down in that case you will get alert on you registered email.

Ping Type→ FreeswitchThreshold will need to set 100 for this. If the freeswitch will go down in that case user will get the alert.
Ping Type→ ConsoleThreshold will need to set 100 for this. If the Console will go down in that case user will get the alert.
Alarm On

This will provide the Alarm Details based on below.

  • Trunk- If the ACD, CIC, ASR is the Alarm Type.
  • Gateway- If the Gateway is the Alarm Type.


As explained in above table configure the alarm details based on requirements as seen in below screenshot. Once Configured then click on the save button.


Go to Switch→ Call Alarms→ Report

Here Alarm Report will open which will give the list of triggered Value which with the same columns explained in the above point for creation of Alarm Configuration.